This bundle contains everything you need to get started:

  • 1x ctrlX CORE X3 - R911410037
  • 1x EtherCAT bus coupler XB-EC-12 ctrlX I/O - R911406090
  • 1x digital input module XI110116 ctrlX I/O 16-channel (24 VDC, 3 ms filter time), 1-wire, PNP - R911406097
  • 1x digital output module XI211116 ctrlX I/O 16-channel (24 VDC, 0.5 A), 1-wire, PNP - R911406102
  • 1x ctrlX CORE License - PLC Basic (01VRS) - R911397817
  • 1x ctrlX OS License - EtherCAT Master Basic - R911400508
  • 1x EtherCAT cable 10cm to connect the bus coupler to the CORE

We install the licenses and can add more at any time!

We also offer 1 hour of free° support when you purchase this bundle.


°at our location in Saarbrücken or within a radius of 75km, otherwise digitally via MS Teams

Technical data

General technical data:

  • Processor: Zync Ultrascale+, 64-bit, 4 × ARM A53
  • Memory: 2 GB DRAM
  • Internal physical memory (eMMC): 4 GB
  • Internal nonvolatile memory (NVRAM): 128 kB
  • Communication interfaces RJ-45: 3 × Ethernet port (10 Mbit, 100 Mbit, 1 Gbit)
  • USB: 1 × USB host, TYPE C (USB2.0), maximum cable length 3 m
  • SD card slot for SD card
  • Battery: CR1025
  • Weight: 370 g

Electrical characteristics:

  • Rated voltage at UL: DC 24 V SELV/PELV
  • Maximum permissible voltage range of the supply voltage UL: DC 18 V to DC 31.2 V (including all tolerances, including ripple)
  • Current consumption of the control from UL at nominal voltage 24 V: 320 mA
  • Power consumption of the control from UL at nominal voltage 24 V: 7.68 W
  • Reverse polarity protection of supply voltage UL: Present
  • Fuse UL: Internal with eFuse, 1.5 A
  • Overvoltage protection UL: Present, in case of overvoltage the fuse can be triggered
  • Transient protection UL: Present, suppressor diodes, pulse load up to 1500 W
  • Voltage dips at power supply interfaces: PS1 < 1 ms, evaluation criterion A, not evaluated by UL
  • Potential isolation: DC 707 V
  • 24 V supply (UL/UL GND) to functional earth: not evaluated by UL
  • 24 V supply voltage (UL/UL GND) to XF10,
    XF50, XF51: DC 1200 V, not evaluated by UL